The following article was written by Stan Honey, electrical engineer and renowned offshore sailor and navigator. It appeared in the October 15, 1996 issue of Practical Sailor magazine. West Marine has found the information it contains still pertains today when grounding the electrical wiring aboard your boat.
Honey is a highly decorated competitive sailor and navigator with a remarkable dual career in technology and offshore racing. His sailing victories include the 2005–06 Volvo Ocean Race and 11 wins in the Pacific Transpac race. He has held speed records for sailing around the world and across both the Pacific and Atlantic Oceans, and was named U.S. Sailing’s 2010 Rolex Yachtsman of the Year. As an engineer and entrepreneur, Honey founded Etak — the company that pioneered consumer automotive navigation systems in the 1980s — and Sportvision, the company responsible for the first-down line technology broadcast in NFL games. His technical expertise in both marine electronics and electrical systems gives this article a level of authority that few authors in the marine industry can match.
- DC Ground
- AC Ground
- Lightning Grounds
- RF Ground
- Bonding and Electrolytic Corrosion Due to Hot Marinas
- Zincs and Protection from Galvanic Corrosion
- Inconsistencies in the Ground Rules
- Summary
Marine Grounding Systems
ground n. 12. Electricity. A large conducting body, such as the earth or an electric circuit connected to the earth, used as an arbitrary zero of potential.
In a normal house on land, the problem of grounding is simple. It consists of the green grounding wire in the AC wiring system and serves the purpose of preventing shocks or electrocution. The ground connection is usually made by clamping to a metal water pipe or by driving a long copper stake into the ground.
On a boat, things are considerably more complicated. In addition to the AC ground, we need a DC ground or return line, a lightning ground, and an RF ground plane for the radio systems. Our first thought might be to simply make the ground connection to a metal thru-hull, propeller shaft, or other underwater metal. This underwater metal, grounded by connection to the seawater, will serve as our water pipe. Unfortunately, a connection between any of these systems and underwater metal can, and probably will, give rise to serious electrolytic corrosion problems. This article will discuss the particular requirements of each system, resolve the contradictions between the systems, and present a consistent and correct solution for a complete, integrated marine grounding system.
Figure 1. The boat’s electrical system should be connected to seawater at one point only, via the engine negative terminal or its bus.
DC Ground
Every light or appliance should be wired with its own DC return wire. Never use the mast, engine, or other metal object as part of the return circuit. The DC load returns of all branch circuits should be tied to the negative bus of the DC distribution panel. In turn, the negative bus of the DC distribution panel should be connected to the engine negative terminal or its bus. The battery negative is also connected to the engine negative terminal or its bus. The key factor here is that the yacht’s electrical system is connected to seawater ground at one point only, via the engine negative terminal or its bus. See Figure 1.
AC Ground
See Practical Sailor, August 15, 1995, for a detailed treatment of the green wire. The best solution is a heavy and expensive isolation transformer. The acceptable solution for the rest of us is to install a light and inexpensive Galvanic Isolator in the green wire, between the shorepower cord socket on your boat and the connection to the boat’s AC panel. Then connect the grounding conductor (green) of the AC panel directly to the engine negative terminal or its bus.
Note that this meets the ABYC recommendation. In choosing Galvanic Isolators, make sure that you select one with a continuous current rating of at least 135% of the current rating on the circuit breaker on your dock box. Certain Galvanic Isolators include large capacitors in parallel with the isolation diodes, which in certain situations theoretically provide better galvanic protection. Unfortunately, these units cost substantially more than conventional Galvanic Isolators. If you feel like spending real money on galvanic isolation, you might as well do it right and buy an isolation transformer.
It is also a good idea to use a Ground Fault Circuit Interrupter (GFCI) in your AC wiring. GFCIs will occasionally “nuisance trip” due to the humidity surrounding the wiring on boats, but the additional safety they offer — particularly to nearby swimmers — in disconnecting power in the presence of ground currents is worth the nuisance. If your GFCI starts to nuisance trip, it is probably a very good idea to track down and clean up your damp wiring in any event.
Figure 2. Ground fault circuit interrupters (GFCI) should be installed in each AC circuit. A GFCI will disconnect power in the presence of ground currents, helping prevent an electrocution.
Lightning Grounds
Connect a 4 AWG battery cable from the base of your aluminum mast to the nearest keel bolt from external ballast. If you have internal ballast, you should install a lightning ground plate. One square foot is recommended for use in salt water; fresh water requires much more. Do not rely on a thru-hull or a sintered bronze radio ground (e.g. Dynaplate) for use as a lightning ground.
For additional comfort, also run a 6 AWG wire from your keel bolt or ground plate to the upper shroud chainplates and to your headstay chainplate. Don’t bother with the backstay if it is interrupted with antenna insulators. Have each of the cables used for lightning ground wires lead as directly as possible to the same keel bolt, with any necessary bends being smooth and gradual.
Given that you have grounded your mast solidly to the ocean, your mast will be at exactly the same electric potential as the ocean. There is no chance that you can dissipate the charge between the ocean and the atmosphere, so don’t bother with a static dissipater at the masthead. Wire “bottle brush” static dissipaters may be useful to dissipate seagulls, however — but that is beyond the scope of this article.
RF Ground
Your VHF doesn’t need to use the ocean as a counterpoise, so here we are dealing only with the ground needed for your HF/SSB radio.
Mount your automatic tuner as close to the backstay as possible, preferably just under the after deck. Run copper ground tape from the tuner to the stern pulpit/lifelines, to the engine, and to a keel bolt. It is good practice to include the HF/SSB radio itself in this network of ground tapes. If the builder of your yacht had the foresight to bond into the hull a length of copper tape or an area of copper mesh, be sure to run a copper ground tape to this as well, and say a blessing for builders such as these. Sintered bronze ground plates (e.g. Dynaplates) can be used as radio grounds in situations where the ballast or engine is unavailable or awkward to connect. If the ballast, engine, and lifelines are available, however, they generally make a high performance ground.
Bonding and Electrolytic Corrosion Due to Hot Marinas
Do not bond any thru-hulls or other immersed metal that can be electrically isolated. Specifically, keep your metal keel/ballast, your metal rudder shaft, your engine/prop, and all thru-hulls electrically isolated from each other and from the engine.
It’s worth understanding the reason. In an increasing number of marinas, there are substantial DC electric currents running through the water. If your bits of immersed metal are bonded, the electric current will take the lower resistance path offered by your boat in preference to the water near your boat. The current will flow into one of your bits of metal, through your bonding wires, and then out another bit of metal. The anodic bit of metal or thru-hull that has the misfortune to be on the “out current” side of the current running through your bonding system will also become “out metal” and will disappear, sometimes rapidly.
Your zinc is only intended to protect against the modest galvanic potentials and therefore currents that are caused by the dissimilar metals that are immersed and electrically connected together on your own boat. Your zinc is incapable of supplying enough galvanic potential to protect against substantial DC currents that may be flowing in the water. These DC currents in the water will cause electrolytic corrosion to your bonded thru-hulls or metal parts.
Zincs and Protection from Galvanic Corrosion
Use zincs to protect against the galvanic currents that are set up by dissimilar metals on your boat that are immersed and in electric contact with one another. The best example is your bronze propeller on a stainless shaft. The best protection is to put a zinc right on the shaft next to the propeller, or a zinc on the propeller nut. An isolated bronze thru-hull doesn’t need protection because it is not in electrical contact with another immersed dissimilar metal. If electrically isolated, high quality marine bronze is electrochemically stable in seawater; nothing good can come from connecting wires to it.
Figure 3. Conductors running from the external keel or ground plate to the mast, stays, and to the metal fuel tank will protect against a lightning strike, and there will be no DC connections to the engine or to the electrical system.
Stainless steel is a special case. Generally, it is a bad idea to use stainless steel underwater, because it can pit. When it pits, the “nobility” of the metal changes locally, and you end up with tiny galvanic couples made up of different parts of the same piece of metal, and the pits grow deeper. One school of thought suggests that if you must use stainless steel underwater (e.g. you need its strength), you should connect a nearby, immersed zinc to it; this protects the stainless steel from itself, reducing the rate of pitting. The electrochemistry of this assertion is compelling enough to recommend that you protect a stainless steel rudder shaft with a zinc.
This may be done by mounting a zinc on the hull near the rudder shaft and electrically connecting it (inside the hull) to the stainless rudder shaft. For the reasons described above, ensure that your metal rudder shaft is not electrically connected to anything else. Your stainless steel propeller shaft will be protected from itself by the same shaft zinc that protects the propeller from the stainless steel shaft. In both cases the pits, if they appear, will appear where the stainless steel is not exposed to the water. Trouble areas are in the cutlass bearing, inside the rudder bearing, and just inside the top of the rudder.
Keep your metal keel/ballast electrically isolated from all other bits of metal. If you have the misfortune to have an external iron or steel keel, however, mount a zinc directly on it to reduce the rate of corrosion. Leave lead keels/ballast isolated.
Figure 4. To avoid making another DC ground to the engine via the HF/SSB radio copper ground strip, fasten the copper tape securely to an insulating piece of phenolic or to a terminal strip, cut a 1/10” gap across the tape, and solder several 0.15 µF ceramic capacitors across the gap.
Inconsistencies in the Ground Rules
So now, you are annoyed with the inconsistencies. We said to leave all bits of immersed metal electrically isolated when we described electrolytic corrosion and hot marinas, but then we said to connect wires and copper tape to your keel and engine for lightning and RF grounds. So what to do?
RF ground. The RF ground needs to be a ground for RF signals only. It does not need to conduct DC, and as described in the “Bonding and Electrolytic Corrosion” section above, you do not want to connect another DC ground to your engine and keel.
The solution is to find a dry, secure place along each of the copper RF ground tapes running to your engine and keel. Fasten the tape securely to an insulating piece of phenolic or to a terminal strip, cut a 1/10-inch gap across the tape, and solder several 0.15 µF ceramic capacitors across the gap. These capacitors will be transparent to the RF, which will be happily grounded by the ground tape system, but they will block any DC currents from running through the RF ground system and will avoid any resulting susceptibility to hot marina electrolytic corrosion. It is worth selecting the capacitors carefully, because they may carry a significant amount of RF current.
Lightning Ground
The lightning ground needs to be a direct DC connection to the keel or to a ground plate to handle currents due to lightning strikes. So how do we keep the keel or ground plate electrically isolated as required in the bonding section above?
The solution is to connect the keel or ground plate directly to the mast, but make sure the mast is not electrically connected to the boat’s DC ground system. If your steaming light, masthead light, tricolor, Windex light, etc. are wired carefully and correctly, they each will have their own DC return wire; there should be no ground connection between their wiring and the mast itself. Make sure that this is the case.
This should also be true of your masthead instruments. The unintended DC connection between mast and DC ground is typically made by the masthead VHF whip, which connects the shield of the coax to the bracket connected to the mast. That shield also connects to the VHF radio, which is DC grounded by its power connection. The easiest solution is to insert what is called an “inner-outer DC block” into the coax.
This RF device puts a capacitor in series with the center conductor and another capacitor in series with the shield. The device is transparent to the VHF RF signals in the center conductor and shield, but blocks any DC current in either the center conductor or shield. This device can be made by a good radio technician, or purchased from radio supply houses, pre-fitted with any kind of coax connection on both ends. The commercial units look like a coax “barrel” connector.
Once the DC connection from the mast to the VHF is broken, check for any other connections with an ohmmeter and straighten out any other wiring errors or unintended connections. If your metal fuel tank is also bonded to the lightning ground system (per ABYC), then make sure that it does not have DC connections either to the engine via the fuel line or to the electrical system via the fuel level sensor. A piece of approved rubber fuel hose in the fuel lines to the engine solves that connection, and a well-designed fuel level sensor will not make electrical contact with the tank.
When you’re done, there will be heavy conductors running from the external keel or lightning ground plate to the mast, stays, and to the metal fuel tank, but there will be no DC connections to the engine or to the yacht’s electrical system. See Figure 3.
Summary
By using capacitors to block DC connections in a few key areas, it is possible to have perfect ground systems for AC, DC, RF, lightning, and corrosion, and have a boat that is immune to stray DC currents traveling through the water in “hot marinas.”
In the old days, the technique of bonding everything together worked okay. In its defense, the “bond everything together” approach makes your boat less sensitive to electrolytic corrosion that can result from faulty wiring on your own boat. The problem is, the “bond everything” approach leaves your boat totally defenseless to wiring errors in nearby boats and nearby industry that cause stray DC currents to run through the water.
Today the technique of bonding everything together would still work fine if your boat spent all of its time on the high seas, in remote anchorages, or in marinas that were wired perfectly and in which all nearby yachts were wired perfectly. Having underwater metal bonded together in crowded marinas today, however, is asking for expensive trouble — and as outlined above, it is avoidable trouble. It is possible, with careful wiring and a few capacitors, to have the best of all worlds: good RF and lightning grounds, ABYC-approved DC and AC grounds, and security against electrolytic corrosion caused by hot marinas.
Frequently Asked Questions: Marine Grounding Systems
What is the difference between galvanic corrosion and electrolytic corrosion on a boat?
Galvanic corrosion is driven by the electrochemical difference between dissimilar metals that are submerged and in electrical contact with each other — for example, a bronze propeller on a stainless steel shaft. This is a natural, always-present phenomenon on any boat with mixed underwater metals. Zincs (sacrificial anodes) are sized and placed to counteract galvanic corrosion from your own boat’s metal combinations. Electrolytic corrosion is driven by externally sourced DC current flowing through the water in a marina — from wiring faults in nearby boats, shore power systems, or industrial equipment. Electrolytic corrosion can be many times more powerful than galvanic corrosion and can destroy underwater metal very rapidly. Zincs cannot protect against it. The solution is electrical isolation of underwater metal from the boat’s bonding system, as described above.
What is a “hot marina” and why is it dangerous?
A hot marina is one in which there are measurable DC electric currents flowing through the water. These can originate from wiring faults in nearby boats, poorly grounded shore power systems, industrial facilities near the marina, or stray currents from other sources. When a boat’s underwater metals are bonded together, the lower-resistance path through the bonding wires becomes a preferred path for these stray currents, which then corrode whichever metal is on the “outflowing” side of the current path. Bonded thru-hulls, propellers, and rudder fittings can be destroyed surprisingly quickly in a hot marina. The solution is to keep underwater metal isolated from the bonding system.
Why shouldn’t I bond all my underwater metal together?
The traditional practice of bonding all underwater metal together provided some protection against galvanic corrosion within the boat’s own system of dissimilar metals. However, in today’s marina environments, bonding creates a low-resistance path for stray DC currents from external sources — other boats, shore power systems, and marina infrastructure. These external currents can cause electrolytic corrosion far more severe than the galvanic corrosion that bonding was intended to prevent. The approach described in this article — keeping underwater metal isolated while using capacitors to maintain RF and lightning grounding without DC connections — provides the benefits of both systems.
Why do you need capacitors in the RF ground system?
The RF ground for your HF/SSB radio needs to be connected to the engine and keel for maximum effectiveness. However, connecting the engine and keel with a direct DC wire would create additional paths for stray marina current to flow through the boat’s underwater metal, causing electrolytic corrosion. Capacitors inserted in the copper ground tape at strategic points solve this problem: they are transparent to radio frequency signals (allowing the RF ground to function normally) but block DC current (preventing electrolytic corrosion paths). The same capacitor principle applies to the coaxial cable from the masthead VHF antenna, where an inner-outer DC block prevents the coax shield from creating an unintended DC connection between the mast and the DC grounding system.
Do I need a zinc on an isolated bronze thru-hull?
No. An isolated bronze thru-hull that is not in electrical contact with any other dissimilar metal does not require cathodic protection. High-quality marine bronze is electrochemically stable in seawater when isolated. Connecting a zinc to an isolated thru-hull actually creates the electrical connection that enables galvanic corrosion in the first place. Leave isolated bronze thru-hulls isolated — do not bond them or attach zincs to them.